Ready to get started?

Download a free trial of the Paylocity ODBC Driver to get started:

 Download Now

Learn more:

Paylocity Icon Paylocity ODBC Driver

The Paylocity ODBC Driver is a powerful tool that allows you to connect with live data from Paylocity, directly from any applications that support ODBC connectivity.

Access Paylocity data like you would a database - read, write, and update Paylocity FALSE, etc. through a standard ODBC Driver interface.

Connect to Paylocity Data as a Linked Server



Use the SQL Gateway and the ODBC Driver to set up a linked server for Paylocity data.

You can use the SQL Gateway to configure a TDS (SQL Server) remoting service and set up a linked server for Paylocity data. After you have started the service, you can use the UI in SQL Server Management Studio or call stored procedures to create the linked server. You can then work with Paylocity data just as you would a linked SQL Server instance.

Connect to Paylocity as an ODBC Data Source

If you have not already, first specify connection properties in an ODBC DSN (data source name). This is the last step of the driver installation. You can use the Microsoft ODBC Data Source Administrator to create and configure ODBC DSNs.

Set the following to establish a connection to Paylocity:

  • RSAPublicKey: Set this to the RSA Key associated with your Paylocity, if the RSA Encryption is enabled in the Paylocity account.

    This property is required for executing Insert and Update statements, and it is not required if the feature is disabled.

  • UseSandbox: Set to true if you are using sandbox account.
  • CustomFieldsCategory: Set this to the Customfields category. This is required when IncludeCustomFields is set to true. The default value for this property is PayrollAndHR.
  • Key: The AES symmetric key(base 64 encoded) encrypted with the Paylocity Public Key. It is the key used to encrypt the content.

    Paylocity will decrypt the AES key using RSA decryption.
    It is an optional property if the IV value not provided, The driver will generate a key internally.

  • IV: The AES IV (base 64 encoded) used when encrypting the content. It is an optional property if the Key value not provided, The driver will generate an IV internally.

Connect Using OAuth Authentication

You must use OAuth to authenticate with Paylocity. OAuth requires the authenticating user to interact with Paylocity using the browser. For more information, refer to the OAuth section in the Help documentation.

The Pay Entry API

The Pay Entry API is completely separate from the rest of the Paylocity API. It uses a separate Client ID and Secret, and must be explicitly requested from Paylocity for access to be granted for an account. The Pay Entry API allows you to automatically submit payroll information for individual employees, and little else. Due to the extremely limited nature of what is offered by the Pay Entry API, we have elected not to give it a separate schema, but it may be enabled via the UsePayEntryAPI connection property.

Please be aware that when setting UsePayEntryAPI to true, you may only use the CreatePayEntryImportBatch & MergePayEntryImportBatchgtable stored procedures, the InputTimeEntry table, and the OAuth stored procedures. Attempts to use other features of the product will result in an error. You must also store your OAuthAccessToken separately, which often means setting a different OAuthSettingsLocation when using this connection property.

Configure the TDS Remoting Service

See the SQL Gateway Overview for a guide to configure a TDS remoting service in the SQL Gateway UI. The TDS remoting service is a daemon process that listens for TDS requests from clients.

Create a Linked Server for Paylocity Data

After you have configured and started the daemon, create the linked server and connect. You can use the UI in SQL Server Management Studio or call stored procedures.

Create a Linked Server from the UI

Follow the steps below to create a linked server from the Object Explorer.

  1. Open SQL Server Management Studio and connect to an instance of SQL Server.
  2. In the Object Explorer, expand the node for the SQL Server database. In the Server Objects node, right-click Linked Servers and click New Linked Server. The New Linked Server dialog is displayed.
  3. In the General section, click the Other Data Source option and enter the following information after naming the linked server:
    • Provider: Select the SQL Server Native Client Provider that corresponds to your version of SQL Server. For example, SQL Server Native Client 11.0.
    • Data Source: Enter the host and port the TDS remoting service is running on, separated by a comma.

      Note that a value of "localhost" in this input refers to the machine where SQL Server is running so be careful when creating a linked server in Management Studio when not running on the same machine as SQL Server.

    • Catalog: Enter the CData system DSN, CData Paylocity Sys.
  4. In the Security section, select the option to have the connection "made using this security context" and enter the username and password of a user you created in the Users tab of the SQL Gateway.

Create a Linked Server Programmatically

In addition to using the SQL Server Management Studio UI to create a linked server, you can use stored procedures. The following inputs are required:

  • server: The linked server name.
  • provider: Enter "SQLNCLI", for the SQL Server Native Client Provider.
  • datasrc: The host and port the service is running on, separated by a comma.

    Note that a value of "localhost" in the datasrc input refers to the machine where SQL Server is running, so be careful when creating a linked server in Management Studio when not running on the same machine as SQL Server.

  • catalog: Enter the system DSN configured for the service.
  • srvproduct: Enter the product name of the data source; this can be an arbitrary value, such as "CData SQL Gateway" or an empty string.
Follow the steps below to create the linked server and configure authentication to the SQL Gateway:
  1. Call sp_addlinkedserver to create the linked server:

    EXEC sp_addlinkedserver @server='Paylocity', @provider='SQLNCLI', @datasrc='< MachineIPAddress >,1434', @catalog='CData Paylocity Sys', @srvproduct=''; GO
  2. Call the sp_addlinkedsrvlogin stored procedure to allow SQL Server users to connect with the credentials of an authorized user of the service. Note that the credentials you use to connect to the service must specify a user you configured on the Users tab of the SQL Gateway.

    EXEC sp_addlinkedsrvlogin @rmtsrvname='Paylocity', @rmtuser='admin', @rmtpassword='test', @useself='FALSE', @locallogin=NULL; GO

Connect from SQL Server Management Studio

SQL Server Management Studio uses the SQL Server Client OLE DB provider, which requires the ODBC driver to be used inprocess. You must enable the "Allow inprocess" option for the SQL Server Native Client Provider in Management Studio to query the linked server from SQL Server Management Studio. To do this, open the properties for the provider you are using under Server Objects -> Linked Servers -> Providers. Check the "Allow inprocess" option and save the changes.

Execute Queries

You can now execute queries to the Paylocity linked server from any tool that can connect to SQL Server. Set the table name accordingly:

SELECT * FROM [linked server name].[CData Paylocity Sys].[Paylocity].[Employee]