Ready to get started?

Download a free trial of the Bullhorn CRM ODBC Driver to get started:

 Download Now

Learn more:

Bullhorn CRM Icon Bullhorn CRM ODBC Driver

The Bullhorn CRM ODBC Driver is a powerful tool that allows you to connect with live data from Bullhorn CRM, directly from any applications that support ODBC connectivity.

Access Bullhorn CRM data like you would a database - read, write, and update Bullhorn CRM Candidates, Resumes, Searches, etc. through a standard ODBC Driver interface.

DataBind Controls to Bullhorn CRM Data in C++Builder



DataBind to Bullhorn CRM data in C++Builder with standard components and controls.

The CData ODBC Driver for Bullhorn CRM makes it easy to integrate connectivity to live Bullhorn CRM data with standard data access components in C++Builder. This article shows how to create a simple visual component library (VCL) application in C++Builder that connects to Bullhorn CRM data, executes queries, and displays the results in a grid. An additional section shows how to use FireDAC components to execute commands from code.

Create a Connection to Bullhorn CRM Data

If you have not already, first specify connection properties in an ODBC DSN (data source name). This is the last step of the driver installation. You can use the Microsoft ODBC Data Source Administrator to create and configure ODBC DSNs.

Begin by providing your Bullhorn CRM account credentials in the following:

If you are uncertain about your data center code, codes like CLS2, CLS21, etc. are cluster IDs that are contained in a user's browser URL (address bar) once they are logged in.

Example: https://cls21.bullhornstaffing.com/BullhornSTAFFING/MainFrame.jsp?#no-ba... indicates that the logged in user is on CLS21.

Authenticating with OAuth

Bullhorn CRM uses the OAuth 2.0 authentication standard. To authenticate using OAuth, create and configure a custom OAuth app. See the Help documentation for more information.

You can then follow the steps below to use the Data Explorer to create a FireDAC connection to Bullhorn CRM.

  1. In a new VCL Forms application, expand the FireDAC node in the Data Explorer.
  2. Right-click the ODBC Data Source node in the Data Explorer.
  3. Click Add New Connection.
  4. Enter a name for the connection.
  5. In the FireDAC Connection Editor that appears, set the DataSource property to the name of the ODBC DSN for Bullhorn CRM.

Create VCL Applications with Connectivity to Bullhorn CRM Data

Follow the procedure below to start querying Bullhorn CRM data from a simple VCL application that displays the results of a query in a grid.

  1. Drop a TFDConnection component onto the form and set the following properties:

    • ConnectionDefName: Select the FireDAC connection to Bullhorn CRM.
    • Connected: Select True from the menu and, in the dialog that appears, enter your credentials.
  2. Drop a TFDQuery component onto the form and set the properties below:

    • Connection: Set this property to the TFDConnection component, if this component is not already specified.
    • SQL: Click the button in the SQL property and enter a query. For example:

      SELECT Id, CandidateName FROM Candidate WHERE CandidateName = 'Jane Doe'
    • Active: Set this property to true.
  3. Drop a TDataSource component onto the form and set the following property:

    • DataSet: In the menu for this property, select the name of the TFDQuery component.
  4. Drop a TDBGrid control onto the form and set the following property:

    • DataSource: Select the name of the TDataSource.
  5. Drop a TFDGUIxWaitCursor onto the form — this is required to avoid a run-time error.

Execute Commands to Bullhorn CRM with FireDAC Components

You can use the TFDConnection and TFQuery components to execute queries to Bullhorn CRM data. This section provides Bullhorn CRM-specific examples of executing queries with the TFQuery component.

Connect to Bullhorn CRM Data

To connect to the data source, set the Connected property of the TFDConnection component to true. You can set the same properties from code:

FDConnection1->ConnectionDefName = "CData Bullhorn CRM ODBC Source"; FDConnection1->Connected = true;

To connect the TFDQuery component to Bullhorn CRM data, set the Connection property of the component. When a TFDQuery component is added at design time, its Connection property is automatically set to point to a TFDConnection on the form, as in the application above.

Create Parameterized Queries

To create a parameterized query, use the following syntax below:

FDQuery1->SQL->Text = "select * from Candidate where candidatename = :CandidateName"; FDQuery1->ParamByName("candidatename")->AsString = "Jane Doe"; query->Open();

The example above binds a string-type input parameter by name and then opens the dataset that results.

Prepare the Statement

Preparing statements is costly in system resources and time. The connection must be active and open while a statement is prepared. By default, FireDAC prepares the query to avoid recompiling the same query over and over. To disable statement preparation, set ResourceOptions.DirectExecute to True; for example, when you need to execute a query only once.

Execute a Query

To execute a query that returns a result set, such as a select query, use the Open method. The Open method executes the query, returns the result set, and opens it. The Open method will return an error if the query does not produce a result set.

FDQuery1->SQL->Text := "select * from Candidate where candidatename = :CandidateName"; FDQuery1.ParamByName("candidatename")->AsString = "Jane Doe"; FDQuery1->Open();

To execute a query that does not return a result set, use the ExecSQL method. The ExecSQL method will return an error if the query returns a result set. To retrieve the count of affected rows use the TFD.RowsAffected property.

FDQ.SQL.Text := "delete from Candidate where Id = :Id"; FDQuery1->Params->Items[0]->AsString = "x12345"; FDQuery1->ExecSQL(); AnsiString i = FDQuery1->RowsAffected;