Discover how a bimodal integration strategy can address the major data management challenges facing your organization today.
Get the Report →Build Semantic Layer Views for Facebook Data in APOS Live Data Gateway
Use the CData Connector for Facebook in APOS Live Data Gateway to build Semantic Layer Views for Facebook data.
APOS Live Data Gateway (LDG) is a data connection and data transformation solution that enables live data connectivity and expanded data source options for SAP Analytics Cloud and other SAP solutions. When paired with CData Connectors, users can build semantic layer views for live Facebook data, enabling real-time analytics on Facebook just like working with a relational database.
With built-in optimized data processing, the CData Connector offers unmatched performance for interacting with live Facebook data. When you issue complex SQL queries to Facebook, the driver pushes supported SQL operations, like filters and aggregations, directly to Facebook and utilizes the embedded SQL engine to process unsupported operations client-side (often SQL functions and JOIN operations). Its built-in dynamic metadata querying allows you to work with and analyze Facebook data using native data types.
Download and Install the Connector Files
In order to access Facebook data through the APOS Live Data Gateway, you will need to download the connector files from APOS and install them on the machine hosting the Live Data Gateway. An APOS representative can deliver the necessary files.
- Install the CData DLL file (System.Data.CData.Facebook.dll) to the APOS Live Data Gateway installation directory (C:\Program Files\Live Data Gateway\Admin\ by default).
- Install the CData JAR file (cdata.jdbc.facebook.jar) to the ConnectionTest_lib folder in the installation directory (C:\Program Files\Live Data Gateway\Admin\ConnectionTest_lib\ by default).
- Install the CData JAR file (cdata.jdbc.facebook.jar) to the lib folder in the Web UI installation directory (e.g.: C:\LDG_WebUI\lib\)
Configuring the Facebook Connection String
Before establishing the connection to Facebook from the APOS Live Data Gateway, you need to configure the Facebook JDBC Connection String.
Built-in Connection String Designer
For assistance in constructing the JDBC Connection String, use the connection string designer built into the Facebook JDBC Driver. Either double-click the JAR file or execute the jar file from the command-line.
java -jar cdata.jdbc.facebook.jar
Fill in the connection properties and copy the connection string to the clipboard.
Most tables require user authentication as well as application authentication. Facebook uses the OAuth authentication standard. To authenticate to Facebook, you can use the embedded OAuthClientId, OAuthClientSecret, and CallbackURL or you can obtain your own by registering an app with Facebook.
See the Getting Started chapter of the help documentation for a guide to using OAuth.
Your connection string will look similar to the following:
jdbc:Facebook:
Connecting to Facebook & Creating a Semantic Layer View
After installing the connector files and configuring the connection string, you are ready to connect to Facebook in the Live Data Gateway Admin tool and build a semantic layer view in the Live Data Gateway Web UI.
Configuring the Connection to Facebook
- Log into your APOS Live Data Gateway Manager
- If you haven't already, update your APOS LDG license file
- Click File -> Configurations
- Click on the "..." Menu for the License
- Select the license file from the APOS team that includes your CData Connector license
- In the APOS Live Data Gateway Manager, click "Add"
- In the APOS Live Data Gateway On the Connection tab, configure the connection:
- Set Data Source to "Database"
- Set Database to "CData Drivers"
- Set Database CData Drivers to "Facebook"
- Set Connection String to the connection string configured earlier (e.g.:
jdbc:Facebook:
- Set Driver Class to "cdata.jdbc.facebook.FacebookDriver" (this should be set by default)
- Click Test Connection
- Click Save
- Give your connection a unique prefix (e.g. "facebook")
- Highlight the newly created connection and click File -> "Approve Users For Web UI"
- Approve the appropriate DB users to create views and click "Save"
At this point, we are ready to build our semantic layer view in the Live Data Gateway Web UI.
Creating a Semantic Layer View
- In your browser, navigate to the APOS Live Data Gateway Portal
- Select a Connection (e.g. "facebook")
- Since Facebook does not require a User or Password to authenticate, you may use whatever values you wish for User Name and Password
- Click "Login"
- Once connected, click "Semantic Layer" to create a new semantic layer view
- Click "New Semantic Layer View"
- Set the Semantic Layer View Prefix and Semantic Layer View Name
- Click "Step 2"
- Select the table(s) and column(s) you wish to include in your view
- Click "Step 3"
- Select the Measures from the available table columns
- Click "Step 5" (we skipped the "Extra Dimensions" step)
- Add any Variable Prompts
- Click "Step 6"
- Define any Table Joins
- Click "Review"
- Review you semantic layer view and click "Save"
With the Semantic Layer View created, you are ready to access your Facebook data through the APOS Live Data Gateway, enabling real-time data connectivity to Facebook data from SAP Analytics Cloud and other SAP solutions.
More Information & Free Evaluation
Please visit APOS Systems - APOS Solutions - Request Evaluation Software to request evaluation software or email [email protected] for more information on working with your live Facebook data in APOS Live Data Gateway.