Ready to get started?

Download a free trial of the FTP Driver to get started:

 Download Now

Learn more:

FTP Icon FTP JDBC Driver

An easy-to-use database-like interface for Java based applications and reporting tools access to remote files and directories.

Build Semantic Layer Views for FTP Data in APOS Live Data Gateway



Use the CData Connector for FTP in APOS Live Data Gateway to build Semantic Layer Views for FTP data.

APOS Live Data Gateway (LDG) is a data connection and data transformation solution that enables live data connectivity and expanded data source options for SAP Analytics Cloud and other SAP solutions. When paired with CData Connectors, users can build semantic layer views for live FTP data, enabling real-time analytics on FTP just like working with a relational database.

With built-in optimized data processing, the CData Connector offers unmatched performance for interacting with live FTP data. When you issue complex SQL queries to FTP, the driver pushes supported SQL operations, like filters and aggregations, directly to FTP and utilizes the embedded SQL engine to process unsupported operations client-side (often SQL functions and JOIN operations). Its built-in dynamic metadata querying allows you to work with and analyze FTP data using native data types.

Download and Install the Connector Files

In order to access FTP data through the APOS Live Data Gateway, you will need to download the connector files from APOS and install them on the machine hosting the Live Data Gateway. An APOS representative can deliver the necessary files.

  • Install the CData DLL file (System.Data.CData.FTP.dll) to the APOS Live Data Gateway installation directory (C:\Program Files\Live Data Gateway\Admin\ by default).
  • Install the CData JAR file (cdata.jdbc.ftp.jar) to the ConnectionTest_lib folder in the installation directory (C:\Program Files\Live Data Gateway\Admin\ConnectionTest_lib\ by default).
  • Install the CData JAR file (cdata.jdbc.ftp.jar) to the lib folder in the Web UI installation directory (e.g.: C:\LDG_WebUI\lib\)

Configuring the FTP Connection String

Before establishing the connection to FTP from the APOS Live Data Gateway, you need to configure the FTP JDBC Connection String.

Built-in Connection String Designer

For assistance in constructing the JDBC Connection String, use the connection string designer built into the FTP JDBC Driver. Either double-click the JAR file or execute the jar file from the command-line.

java -jar cdata.jdbc.ftp.jar

Fill in the connection properties and copy the connection string to the clipboard.

To connect to FTP or SFTP servers, specify at least RemoteHost and FileProtocol. Specify the port with RemotePort.

Set User and Password to perform Basic authentication. Set SSHAuthMode to use SSH authentication. See the Getting Started section of the data provider help documentation for more information on authenticating via SSH.

Set SSLMode and SSLServerCert to secure connections with SSL.

The data provider lists the tables based on the available folders in your FTP server. Set the following connection properties to control the relational view of the file system:

  • RemotePath: Set this to the current working directory.
  • TableDepth: Set this to control the depth of folders to list as views.
  • FileRetrievalDepth: Set this to retrieve and list files recursively from the root table.

Stored Procedures are available to download files, upload files, and send protocol commands. See the Data Model chapter of the FTP data provider documentation for more information.

Your connection string will look similar to the following:

jdbc:FTP:RemoteHost=MyFTPServer;

Connecting to FTP & Creating a Semantic Layer View

After installing the connector files and configuring the connection string, you are ready to connect to FTP in the Live Data Gateway Admin tool and build a semantic layer view in the Live Data Gateway Web UI.

Configuring the Connection to FTP

  1. Log into your APOS Live Data Gateway Manager
  2. If you haven't already, update your APOS LDG license file
    1. Click File -> Configurations
    2. Click on the "..." Menu for the License
    3. Select the license file from the APOS team that includes your CData Connector license
  3. In the APOS Live Data Gateway Manager, click "Add"
  4. In the APOS Live Data Gateway On the Connection tab, configure the connection:
    • Set Data Source to "Database"
    • Set Database to "CData Drivers"
    • Set Database CData Drivers to "FTP"
    • Set Connection String to the connection string configured earlier (e.g.: jdbc:FTP:RemoteHost=MyFTPServer;
    • Set Driver Class to "cdata.jdbc.ftp.FTPDriver" (this should be set by default)
  5. Click Test Connection
  6. Click Save
  7. Give your connection a unique prefix (e.g. "ftp")
  8. Highlight the newly created connection and click File -> "Approve Users For Web UI"
  9. Approve the appropriate DB users to create views and click "Save"

At this point, we are ready to build our semantic layer view in the Live Data Gateway Web UI.

Creating a Semantic Layer View

  1. In your browser, navigate to the APOS Live Data Gateway Portal
  2. Select a Connection (e.g. "ftp")
  3. Since FTP does not require a User or Password to authenticate, you may use whatever values you wish for User Name and Password
  4. Click "Login"
  5. Once connected, click "Semantic Layer" to create a new semantic layer view
  6. Click "New Semantic Layer View"
  7. Set the Semantic Layer View Prefix and Semantic Layer View Name
  8. Click "Step 2"
  9. Select the table(s) and column(s) you wish to include in your view
  10. Click "Step 3"
  11. Select the Measures from the available table columns
  12. Click "Step 5" (we skipped the "Extra Dimensions" step)
  13. Add any Variable Prompts
  14. Click "Step 6"
  15. Define any Table Joins
  16. Click "Review"
  17. Review you semantic layer view and click "Save"

With the Semantic Layer View created, you are ready to access your FTP data through the APOS Live Data Gateway, enabling real-time data connectivity to FTP data from SAP Analytics Cloud and other SAP solutions.

More Information & Free Evaluation

Please visit APOS Systems - APOS Solutions - Request Evaluation Software to request evaluation software or email info@apos.com for more information on working with your live FTP data in APOS Live Data Gateway.