Extract, Transform, and Load SharePoint Data in Informatica PowerCenter



Create a simple Workflow for SharePoint data in Informatica PowerCenter.

Informatica provides a powerful, elegant means of transporting and transforming your data. By utilizing the CData ODBC Driver for SharePoint, you are gaining access to a driver based on industry-proven standards that integrates seamlessly with Informatica's powerful data transportation and manipulation features. This tutorial shows how to create a simple Workflow in Informatica PowerCenter to extract SharePoint data and load it into a flat file.

About SharePoint Data Integration

Accessing and integrating live data from SharePoint has never been easier with CData. Customers rely on CData connectivity to:

  • Access data from a wide range of SharePoint versions, including Windows SharePoint Services 3.0, Microsoft Office SharePoint Server 2007 and above, and SharePoint Online.
  • Access all of SharePoint thanks to support for Hidden and Lookup columns.
  • Recursively scan folders to create a relational model of all SharePoint data.
  • Use SQL stored procedures to upload and download documents and attachments.

Most customers rely on CData solutions to integrate SharePoint data into their database or data warehouse, while others integrate their SharePoint data with preferred data tools, like Power BI, Tableau, or Excel.

For more information on how customers are solving problems with CData's SharePoint solutions, refer to our blog: Drivers in Focus: Collaboration Tools.


Getting Started


Add SharePoint as an ODBC Data Source

If you have not already, install the driver on the PowerCenter server and client machines. On both machines, specify the connection properties in an ODBC DSN (data source name). This is the last step of the driver installation. You can use the Microsoft ODBC Data Source Administrator to create and configure ODBC DSNs.

Set the URL property to the base SharePoint site or to a sub-site. This allows you to query any lists and other SharePoint entities defined for the site or sub-site.

The User and Password properties, under the Authentication section, must be set to valid SharePoint user credentials when using SharePoint On-Premise.

If you are connecting to SharePoint Online, set the SharePointEdition to SHAREPOINTONLINE along with the User and Password connection string properties. For more details on connecting to SharePoint Online, see the "Getting Started" chapter of the help documentation

Create an ETL Workflow in PowerCenter

Follow the steps below to create a workflow in PowerCenter to pull SharePoint data and push it into a flat file.

Create a Source Using the ODBC Driver

  1. In PowerCenter Workflow Manager, add a new ODBC relational connection by going to Connections -> Relational, and in the first window select the ODBC type and click New.
  2. In the Relational Connection Editor, set the name of the newly created connection and set the User Name and Password based on the credentials utilized to connect to your Repository. Under the Connection String input your System DSN, which by default is called 'CData SharePoint Sys'.
  3. In PowerCenter Designer, connect to your repository and open your folder. If you do not already have a folder created, you will need to manually create a folder for your repository. To create a folder, open Informatica PowerCenter Repository Manager, connect to your Repository Service and go to Folder -> Create to create a new folder.
  4. Select the Source Analyzer, click the sources menu, and select Import from Database...
  5. In the drop-down menu for ODBC data source, select the DSN you previously configured (CData SharePoint Sys).
  6. Click connect and select the tables and views to include.
  7. Click OK.

Create a Flat File Target Based on the Source

  1. Select the Target Designer and drag and drop the previously created source onto the workspace. Using the existing source copies the columns into the target.
  2. Right-click the new target, click edit, and change the database type to flat file.

Create a Mapping to Between SharePoint Data and a Flat File

  1. Click on the Mapping Designer.
  2. Drag the source and target to the workspace (name the new mapping, if prompted).
  3. Right-click on the workspace and select Autolink by Name.
  4. Drag the columns from the source qualifier to the target definition.
  5. Save the folder (Ctrl + S).

Create Workflow Based on the Mapping

With the source, target, and mapping created and saved, you are now ready to create the workflow.

  1. Right-click the mapping and select generate workflow to open the Workflow Generation wizard.
  2. Create a workflow with a non-reusable session.
  3. Ensure that you have properly configured the connection object and set the prefixes. If you have not already done so, you will need to create an Integration Service. To create an Integration Service, open your Administrator site, and under Domain, create a new PowerCenter Integration Service. Under the PowerCenter Repository Service, select the Repository you are referring to, and as Username and Password, use your Administrator login information.
  4. Configure the Connection as needed.
  5. Review the Workflow and click Finish.

With a workflow created, you can open the PowerCenter Workflow Manager to access and start the workflow, quickly transferring SharePoint data into a flat file. With the CData ODBC Driver for SharePoint, you can configure sources and targets in PowerCenter to integrate SharePoint data into any of the elegant and powerful features in Informatica PowerCenter.

Ready to get started?

Download a free trial of the SharePoint ODBC Driver to get started:

 Download Now

Learn more:

SharePoint Icon SharePoint ODBC Driver

The SharePoint ODBC Driver is a powerful tool that allows you to connect with live data from SharePoint and SharePoint Online, directly from any applications that support ODBC connectivity.

Access SharePoint data like you would a database - read, write, and update SharePoint Lists, Contacts, Calendar, Links, Tasks, etc. through a standard ODBC Driver interface.