Ready to get started?

Learn more about the CData BizTalk Adapter for UPS or download a free trial:

Download Now

How to Generate SQL Command Schemas for the CData BizTalk Adapter for UPS

The CData BizTalk Adapter makes it easy to process UPS data in BizTalk by returning the data as XML. You can use this data in a BizTalk orchestration by creating an XML schema file for the table you want to access in BizTalk.

This article will show how to generate a schema to process UPS data retrieved using the CData BizTalk Adapter. You will generate a schema for a SELECT command.

This guide shows how to use the CData BizTalk Adapter for UPS to execute SQL commands to UPS.

Add the Adapter for UPS to Your Project

Follow the steps below to add the adapter to a BizTalk Server project.

  1. If you have not already done so, create a new BizTalk Server project in Visual Studio.
  2. Right-click on the project in the Solution Explorer and click Add -> Add Generated Items.
  3. Select Add Adapter Metadata in the resulting dialog box.
  4. In the resulting Add Adapter wizard, select the adapter from the list.
  5. In the Port menu, leave the selection blank. You can also select a receive location or send port that has the adapter configured as its transport type.

Generate a Schema for an SQL Command

After you select the adapter in the Add Adapter wizard, the Schema wizard is displayed. Follow the steps below to configure connection properties and retrieve the metadata for the results of the command.

  1. In the Connection String page, enter authentication credentials and other connection properties, if you did not select an adapter that you have already configured in your BizTalk application. Below is a typical connection string: Server=https://wwwcie.ups.com/ups.app/xml;AccessKey=myAccessKey;Password=myPassword;AccountNumber=myAccountNumber;UserId=myUserIdInitiateOAuth=GETANDREFRESH

    The driver uses five pieces of information in order to authenticate its actions with the UPS service.

    • Server: This controls the URL where the requests should be sent. Common testing options for this are: https://wwwcie.ups.com/ups.app/xml and https://wwwcie.ups.com/webservices
    • AccessKey: This is an identifier that is required to connect to a UPS Server. This value will be provided to you by UPS after registration.
    • UserId: This value is used for logging into UPS. This value is the one you chose to login with when registering for service with UPS.
    • Password: This value is used for logging into UPS. This value is the one you chose to login with when registering for service with UPS.
    • AccountNumber: This is a valid 6-digit or 10-digit UPS account number.
    • PrintLabelLocation: This property is required if one intends to use the GenerateLabels or GenerateReturnLabels stored procedures. This should be set to the folder location where generated labels should be stored.

  2. In the General Options section on the next page, Schema Information, select Send Port or Receive Location, depending on the adapter configuration.
  3. If you want to generate the schema for the entire result set, select the Single Message option in the Message Mode menu. If you want to generate one schema for each row in the result set, select the Message Per Row option and confirm that the root element of the message is 'row'.
  4. In the Command Type menu, select SQL Command.
  5. In the SQL Command Text box on the Statement Information page, enter an SQL command. (If you have configured a receive location or send port, the SQL command you configured is entered in the box.) This example uses the query below:

    SELECT FirstName, Phone FROM Senders WHERE SenderID = '25'

  6. Confirm the settings in the summary displayed by the wizard and click Finish to generate the schema.xsd file.

Processing Schemas

To use schemas in a simple BizTalk application, see the tutorial.