Integrating the CData JDBC Driver for SAP SuccessFactors with Ignition SCADA
Ignition is an industrial supervisory control and data acquisition (SCADA) and industrial Internet of Things (IIoT) platform from Inductive Automation. Its central Gateway service manages device connections, tags, and database connections. Ignition doesn't ship with a connector for SAP SuccessFactors, so reaching SAP SuccessFactors data usually means custom middleware or manual exports.
The CData JDBC Driver for SAP SuccessFactors bridges this gap by exposing SAP SuccessFactors as a standard Java Database Connectivity (JDBC) data source. Ignition treats any JDBC driver as a standard database connection. Once the driver is registered in the Gateway, you can query live SAP SuccessFactors data from the Script Console, SQL Bridge, tags, or a Perspective or Vision screen, without replication, custom connectors, or extract, transform, load (ETL) pipelines.
This guide outlines the steps to install and commission Ignition, register the CData JDBC Driver for SAP SuccessFactors, create the connection, and verify it with a live query.
Prerequisites
- Ignition for Windows (Windows 10/11 or Windows Server), with administrator rights to install a Windows service
- CData JDBC Driver for SAP SuccessFactors
- A SAP SuccessFactors account with valid credentials and application programming interface (API) access enabled
- A supported desktop browser (Google Chrome, Mozilla Firefox, Microsoft Edge, or Safari) to open the Gateway web interface
Step 1: Install and set up Ignition
If Ignition is already installed and running, skip to Step 2.
Download Ignition
-
Go to the Inductive Automation downloads page and download Ignition for Windows.
- This single download is the full Ignition Gateway installer. It includes both the Gateway service and the Designer Launcher, so you don't need a separate Designer download.
Install Ignition
- Run the installer, accept the license agreement, and choose an install location.
- Leave Install as a Windows Service checked so the Gateway starts with Windows.
- Finish the installer. The Gateway service starts, and a browser window opens to http://localhost:8088 and shows the Commissioning wizard. If the page shows a Browser Not Supported notice, open the same address in Chrome, Firefox, Edge, or Safari.
Commission the Gateway
- In the Commission Ignition Gateway wizard, set a Gateway Name and create an administrator username and password.
- Accept the End User License Agreement, then start a trial or activate a purchased Ignition license.
-
When commissioning finishes, log in with the administrator account. You land on the Gateway Home page.
Note: A trial shows a countdown timer on every Gateway page, and the timer resets when the Gateway service restarts. This is fine for testing, but production use requires a license.
Step 2: Register the CData JDBC Driver in Ignition
Ignition lets you upload any third-party JDBC driver through the Gateway web interface, without touching the file system directly.
- Log in to the Gateway as an administrator.
- Go to Connections > Databases > Settings, open the Drivers tab, and click Create JDBC Driver.
-
In the dialog, enter the following:
- Name: SAP SuccessFactors
- Classname: cdata.jdbc.sapsuccessfactors.SAPSuccessFactorsDriver
- Driver Type: Generic
- Default Validation Query: SELECT address1 FROM ExtAddressInfo LIMIT 1
- Click Create JDBC Driver. In current Ignition 8.3 releases, the create dialog doesn't include a Java archive (JAR) file upload field, so you add the JAR file in the next step.
- Open the menu at the right of the new driver row, choose Manage JAR files, upload cdata.jdbc.sapsuccessfactors.jar from the lib folder of the driver installation, and save.
-
Confirm the driver shows an INSTALLED status in the drivers list.
Step 3: Create the SAP SuccessFactors connection
- Go to Connections > Databases > Connections and click Create Database Connection.
-
On the Driver Selection step, select SAP SuccessFactors and click Next.
- On the Database Setup step, set the Name to SAP SuccessFactors. Leave Username empty and select None for Password, because the credentials go in the connect URL.
-
In Connect URL, enter the connection string:
jdbc:sapsuccessfactors:User=username;Password=password;CompanyId=CompanyId;Url=https://api4.successfactors.com;
-
Click Create Database Connection and confirm the connection shows a VALID status on the Database Connections page.
Connection properties for SAP SuccessFactors
You can authenticate to SAP Success Factors using Basic authentication or OAuth with SAML assertion.
Basic Authentication
You must provide values for the following properties to successfully authenticate to SAP Success Factors. Note that the provider will reuse the session opened by SAP Success Factors using cookies. Which means that your credentials will be used only on the first request to open the session. After that, cookies returned from SAP Success Factors will be used for authentication.
- Url: set this to the URL of the server hosting Success Factors. Some of the servers are listed in the SAP support documentation (external link).
- User: set this to the username of your account.
- Password: set this to the password of your account.
- CompanyId: set this to the unique identifier of your company.
OAuth Authentication
You must provide values for the following properties, which will be used to get the access token.
- Url: set this to the URL of the server hosting Success Factors. Some of the servers are listed in the SAP support documentation (external link).
- User: set this to the username of your account.
- CompanyId: set this to the unique identifier of your company.
- OAuthClientId: set this to the API Key that was generated in API Center.
- OAuthClientSecret: the X.509 private key used to sign SAML assertion. The private key can be found in the certificate you downloaded in Registering your OAuth Client Application.
- InitiateOAuth: set this to GETANDREFRESH.
Note: If a password or token contains a semicolon, the connect URL breaks, so reset it to a value without one.
Step 4: Query live SAP SuccessFactors data from Ignition
With the connection valid, you can query live SAP SuccessFactors data from the Designer.
-
Open the Ignition Designer Launcher, select your Gateway (click Add Designer and enter http://localhost:8088 if it isn't listed), and click Open Designer. Log in with the Gateway administrator account.
-
Open or create a project. The Designer opens with the Project Browser, Tag Browser, and Component Palette panels.
-
In the Designer, go to Tools > Script Console. In the Multiline Buffer, enter a test query and click Execute. Replace ExtAddressInfo with any table available in your SAP SuccessFactors connection:
print system.db.runQuery( "SELECT address1, zipCode FROM ExtAddressInfo LIMIT 10", "SAP SuccessFactors")
- A successful query prints PyDataset rows:10 cols:2 in the Interactive Interpreter panel, which confirms Ignition retrieved live data from SAP SuccessFactors through the CData JDBC Driver.
Note: The connection name in the script must match the name you gave the connection in Step 3.
Step 5: Verify the results
-
Print the rows and compare the values with the same records in SAP SuccessFactors:
ds = system.db.runQuery("SELECT address1, zipCode FROM ExtAddressInfo LIMIT 10", "SAP SuccessFactors") for row in ds: print row["address1"], row["zipCode"] - Optionally, run a second query against another table and a filtered query to confirm schema discovery and filtering.
- Optionally, restart the Gateway service and confirm the connection returns to VALID.
Troubleshooting
| Symptom | Likely cause and fix |
|---|---|
| Driver status shows ERROR | The classname is wrong, or the JAR file hasn't been uploaded through Manage JAR files. |
| Connection status shows FAULTED | The credentials are wrong, outbound web traffic (HTTPS) is blocked, or the CData license isn't found. Click the status to read the error. |
| Error: Could not find a valid license | The Gateway runs as a Windows service and can't read a license stored in your user profile. In an administrator command prompt, run java -jar cdata.jdbc.sapsuccessfactors.jar --license from the driver's lib folder, copy the generated .lic file to C:\Windows\system32\config\systemprofile\.CData\, and restart the Gateway service. |
| Database connection not found | The connection name in the script doesn't match the Gateway connection name exactly. |
Test the driver outside Ignition
To confirm the driver works independently of the Gateway, run this standalone Java example. The cdata.jdbc.sapsuccessfactors.jar and cdata.jdbc.sapsuccessfactors.lic files must be in the same directory and on the classpath.
import java.sql.Connection;
import java.sql.DriverManager;
import java.sql.ResultSet;
import java.sql.Statement;
public class CDataExample {
public static void main(String[] args) throws Exception {
Class.forName("cdata.jdbc.sapsuccessfactors.SAPSuccessFactorsDriver");
String connectionString = "jdbc:sapsuccessfactors:User=username;Password=password;CompanyId=CompanyId;Url=https://api4.successfactors.com;";
try (Connection conn = DriverManager.getConnection(connectionString)) {
Statement stmt = conn.createStatement();
ResultSet rs = stmt.executeQuery("SELECT address1, zipCode FROM ExtAddressInfo LIMIT 10");
while (rs.next()) {
System.out.println(rs.getString("address1") + ", " + rs.getString("zipCode"));
}
}
}
}
Build live, governed SAP SuccessFactors connectivity in Ignition with CData
With the CData JDBC Driver for SAP SuccessFactors registered, your team can query live SAP SuccessFactors data from Ignition without ETL infrastructure, manual exports, or custom integration code, and reuse the same connection in tags, SQL Bridge, and Perspective or Vision screens.
Start your free trial today to see how you can give Ignition live, secure access to hundreds of external systems with CData.