Integrating the CData JDBC Driver for Jira with Ignition SCADA
Ignition is an industrial supervisory control and data acquisition (SCADA) and industrial Internet of Things (IIoT) platform from Inductive Automation. Its central Gateway service manages device connections, tags, and database connections. Ignition doesn't ship with a connector for Jira, so reaching Jira data usually means custom middleware or manual exports.
The CData JDBC Driver for Jira bridges this gap by exposing Jira as a standard Java Database Connectivity (JDBC) data source. Ignition treats any JDBC driver as a standard database connection. Once the driver is registered in the Gateway, you can query live Jira data from the Script Console, SQL Bridge, tags, or a Perspective or Vision screen, without replication, custom connectors, or extract, transform, load (ETL) pipelines.
This guide outlines the steps to install and commission Ignition, register the CData JDBC Driver for Jira, create the connection, and verify it with a live query.
Prerequisites
- Ignition for Windows (Windows 10/11 or Windows Server), with administrator rights to install a Windows service
- CData JDBC Driver for Jira
- A Jira account with valid credentials and application programming interface (API) access enabled
- A supported desktop browser (Google Chrome, Mozilla Firefox, Microsoft Edge, or Safari) to open the Gateway web interface
About Jira Data Integration
CData simplifies access and integration of live Jira data. Our customers leverage CData connectivity to:
- Gain bi-directional access to their Jira objects like issues, projects, and workflows.
- Use SQL stored procedures to perform functional actions like changing issues status, creating custom fields, download or uploading an attachment, modifying or retrieving time tracking settings, and more.
- Authenticate securely using a variety of methods, including username and password, OAuth, personal access token, API token, Crowd or OKTA SSO, LDAP, and more.
Most users leverage CData solutions to integrate Jira data with their database or data warehouse, whether that's using CData Sync directly or relying on CData's compatibility with platforms like SSIS or Azure Data Factory. Others are looking to get analytics and reporting on live Jira data from preferred analytics tools like Tableau and Power BI.
Learn more about how customers are seamlessly connecting to their Jira data to solve business problems from our blog: Drivers in Focus: Collaboration Tools.
Getting Started
Step 1: Install and set up Ignition
If Ignition is already installed and running, skip to Step 2.
Download Ignition
-
Go to the Inductive Automation downloads page and download Ignition for Windows.
- This single download is the full Ignition Gateway installer. It includes both the Gateway service and the Designer Launcher, so you don't need a separate Designer download.
Install Ignition
- Run the installer, accept the license agreement, and choose an install location.
- Leave Install as a Windows Service checked so the Gateway starts with Windows.
- Finish the installer. The Gateway service starts, and a browser window opens to http://localhost:8088 and shows the Commissioning wizard. If the page shows a Browser Not Supported notice, open the same address in Chrome, Firefox, Edge, or Safari.
Commission the Gateway
- In the Commission Ignition Gateway wizard, set a Gateway Name and create an administrator username and password.
- Accept the End User License Agreement, then start a trial or activate a purchased Ignition license.
-
When commissioning finishes, log in with the administrator account. You land on the Gateway Home page.
Note: A trial shows a countdown timer on every Gateway page, and the timer resets when the Gateway service restarts. This is fine for testing, but production use requires a license.
Step 2: Register the CData JDBC Driver in Ignition
Ignition lets you upload any third-party JDBC driver through the Gateway web interface, without touching the file system directly.
- Log in to the Gateway as an administrator.
- Go to Connections > Databases > Settings, open the Drivers tab, and click Create JDBC Driver.
-
In the dialog, enter the following:
- Name: Jira
- Classname: cdata.jdbc.jira.JIRADriver
- Driver Type: Generic
- Default Validation Query: SELECT Summary FROM Issues LIMIT 1
- Click Create JDBC Driver. In current Ignition 8.3 releases, the create dialog doesn't include a Java archive (JAR) file upload field, so you add the JAR file in the next step.
- Open the menu at the right of the new driver row, choose Manage JAR files, upload cdata.jdbc.jira.jar from the lib folder of the driver installation, and save.
-
Confirm the driver shows an INSTALLED status in the drivers list.
Step 3: Create the Jira connection
- Go to Connections > Databases > Connections and click Create Database Connection.
-
On the Driver Selection step, select Jira and click Next.
- On the Database Setup step, set the Name to Jira. Leave Username empty and select None for Password, because the credentials go in the connect URL.
-
In Connect URL, enter the connection string:
jdbc:jira:User=admin;Password=123abc;Url=https://yoursitename.atlassian.net;
-
Click Create Database Connection and confirm the connection shows a VALID status on the Database Connections page.
Connection properties for Jira
To connect to JIRA, provide the User and Password. Additionally, provide the Url; for example, https://yoursitename.atlassian.net.
Note: If a password or token contains a semicolon, the connect URL breaks, so reset it to a value without one.
Step 4: Query live Jira data from Ignition
With the connection valid, you can query live Jira data from the Designer.
-
Open the Ignition Designer Launcher, select your Gateway (click Add Designer and enter http://localhost:8088 if it isn't listed), and click Open Designer. Log in with the Gateway administrator account.
-
Open or create a project. The Designer opens with the Project Browser, Tag Browser, and Component Palette panels.
-
In the Designer, go to Tools > Script Console. In the Multiline Buffer, enter a test query and click Execute. Replace Issues with any table available in your Jira connection:
print system.db.runQuery( "SELECT Summary, TimeSpent FROM Issues LIMIT 10", "Jira")
- A successful query prints PyDataset rows:10 cols:2 in the Interactive Interpreter panel, which confirms Ignition retrieved live data from Jira through the CData JDBC Driver.
Note: The connection name in the script must match the name you gave the connection in Step 3.
Step 5: Verify the results
-
Print the rows and compare the values with the same records in Jira:
ds = system.db.runQuery("SELECT Summary, TimeSpent FROM Issues LIMIT 10", "Jira") for row in ds: print row["Summary"], row["TimeSpent"] - Optionally, run a second query against another table and a filtered query to confirm schema discovery and filtering.
- Optionally, restart the Gateway service and confirm the connection returns to VALID.
Troubleshooting
| Symptom | Likely cause and fix |
|---|---|
| Driver status shows ERROR | The classname is wrong, or the JAR file hasn't been uploaded through Manage JAR files. |
| Connection status shows FAULTED | The credentials are wrong, outbound web traffic (HTTPS) is blocked, or the CData license isn't found. Click the status to read the error. |
| Error: Could not find a valid license | The Gateway runs as a Windows service and can't read a license stored in your user profile. In an administrator command prompt, run java -jar cdata.jdbc.jira.jar --license from the driver's lib folder, copy the generated .lic file to C:\Windows\system32\config\systemprofile\.CData\, and restart the Gateway service. |
| Database connection not found | The connection name in the script doesn't match the Gateway connection name exactly. |
Test the driver outside Ignition
To confirm the driver works independently of the Gateway, run this standalone Java example. The cdata.jdbc.jira.jar and cdata.jdbc.jira.lic files must be in the same directory and on the classpath.
import java.sql.Connection;
import java.sql.DriverManager;
import java.sql.ResultSet;
import java.sql.Statement;
public class CDataExample {
public static void main(String[] args) throws Exception {
Class.forName("cdata.jdbc.jira.JIRADriver");
String connectionString = "jdbc:jira:User=admin;Password=123abc;Url=https://yoursitename.atlassian.net;";
try (Connection conn = DriverManager.getConnection(connectionString)) {
Statement stmt = conn.createStatement();
ResultSet rs = stmt.executeQuery("SELECT Summary, TimeSpent FROM Issues LIMIT 10");
while (rs.next()) {
System.out.println(rs.getString("Summary") + ", " + rs.getString("TimeSpent"));
}
}
}
}
Build live, governed Jira connectivity in Ignition with CData
With the CData JDBC Driver for Jira registered, your team can query live Jira data from Ignition without ETL infrastructure, manual exports, or custom integration code, and reuse the same connection in tags, SQL Bridge, and Perspective or Vision screens.
Start your free trial today to see how you can give Ignition live, secure access to hundreds of external systems with CData.