Ready to get started?

Connect to live data from Harvest with the API Driver

Connect to Harvest

Build Semantic Layer Views for Harvest Data in APOS Live Data Gateway



Use the CData Connector for Harvest in APOS Live Data Gateway to build Semantic Layer Views for Harvest data.

APOS Live Data Gateway (LDG) is a data connection and data transformation solution that enables live data connectivity and expanded data source options for SAP Analytics Cloud and other SAP solutions. When paired with CData Connectors, users can build semantic layer views for live Harvest data, enabling real-time analytics on Harvest just like working with a relational database.

With built-in optimized data processing, the CData Connector offers unmatched performance for interacting with live Harvest data. When you issue complex SQL queries to Harvest, the driver pushes supported SQL operations, like filters and aggregations, directly to Harvest and utilizes the embedded SQL engine to process unsupported operations client-side (often SQL functions and JOIN operations). Its built-in dynamic metadata querying allows you to work with and analyze Harvest data using native data types.

Download and Install the Connector Files

In order to access Harvest data through the APOS Live Data Gateway, you will need to download the connector files from APOS and install them on the machine hosting the Live Data Gateway. An APOS representative can deliver the necessary files.

  • Install the CData DLL file (System.Data.CData.API.dll) to the APOS Live Data Gateway installation directory (C:\Program Files\Live Data Gateway\Admin\ by default).
  • Install the CData JAR file (cdata.jdbc.api.jar) to the ConnectionTest_lib folder in the installation directory (C:\Program Files\Live Data Gateway\Admin\ConnectionTest_lib\ by default).
  • Install the CData JAR file (cdata.jdbc.api.jar) to the lib folder in the Web UI installation directory (e.g.: C:\LDG_WebUI\lib\)

Configuring the Harvest Connection String

Before establishing the connection to Harvest from the APOS Live Data Gateway, you need to configure the Harvest JDBC Connection String.

Built-in Connection String Designer

For assistance in constructing the JDBC Connection String, use the connection string designer built into the Harvest JDBC Driver. Either double-click the JAR file or execute the jar file from the command-line.

java -jar cdata.jdbc.api.jar

Fill in the connection properties and copy the connection string to the clipboard.

Start by setting the Profile connection property to the location of the Harvest Profile on disk (e.g. C:\profiles\Harvest.apip). Next, set the ProfileSettings connection property to the connection string for Harvest (see below).

Harvest API Profile Settings

To authenticate to Harvest, you can use either Token authentication or the OAuth standard. Use Basic authentication to connect to your own data. Use OAuth to allow other users to connect to their data.

Using Token Authentication

To use Token Authentication, set the APIKey to your Harvest Personal Access Token in the ProfileSettings connection property. In addition to APIKey, set your AccountId in ProfileSettings to connect.

Using OAuth Authentication

First, register an OAuth2 application with Harvest. The application can be created from the "Developers" section of Harvest ID.

After setting the following connection properties, you are ready to connect:

  • ProfileSettings: Set your AccountId in ProfileSettings.
  • AuthScheme: Set this to OAuth.
  • OAuthClientId: Set this to the client ID that you specified in your app settings.
  • OAuthClientSecret: Set this to the client secret that you specified in your app settings.
  • CallbackURL: Set this to the Redirect URI that you specified in your app settings.
  • InitiateOAuth: Set this to GETANDREFRESH. You can use InitiateOAuth to manage how the driver obtains and refreshes the OAuthAccessToken.

Your connection string will look similar to the following:

jdbc:API:Profile=C:\profiles\Harvest.apip;ProfileSettings='APIKey=my_personal_key;AccountId=_your_account_id';

Connecting to Harvest & Creating a Semantic Layer View

After installing the connector files and configuring the connection string, you are ready to connect to Harvest in the Live Data Gateway Admin tool and build a semantic layer view in the Live Data Gateway Web UI.

Configuring the Connection to Harvest

  1. Log into your APOS Live Data Gateway Manager
  2. If you haven't already, update your APOS LDG license file
    1. Click File -> Configurations
    2. Click on the "..." Menu for the License
    3. Select the license file from the APOS team that includes your CData Connector license
  3. In the APOS Live Data Gateway Manager, click "Add"
  4. In the APOS Live Data Gateway On the Connection tab, configure the connection:
    • Set Data Source to "Database"
    • Set Database to "CData Drivers"
    • Set Database CData Drivers to "Harvest"
    • Set Connection String to the connection string configured earlier (e.g.: jdbc:API:Profile=C:\profiles\Harvest.apip;ProfileSettings='APIKey=my_personal_key;AccountId=_your_account_id';
    • Set Driver Class to "cdata.jdbc.api.APIDriver" (this should be set by default)
  5. Click Test Connection
  6. Click Save
  7. Give your connection a unique prefix (e.g. "api")
  8. Highlight the newly created connection and click File -> "Approve Users For Web UI"
  9. Approve the appropriate DB users to create views and click "Save"

At this point, we are ready to build our semantic layer view in the Live Data Gateway Web UI.

Creating a Semantic Layer View

  1. In your browser, navigate to the APOS Live Data Gateway Portal
  2. Select a Connection (e.g. "api")
  3. Since Harvest does not require a User or Password to authenticate, you may use whatever values you wish for User Name and Password
  4. Click "Login"
  5. Once connected, click "Semantic Layer" to create a new semantic layer view
  6. Click "New Semantic Layer View"
  7. Set the Semantic Layer View Prefix and Semantic Layer View Name
  8. Click "Step 2"
  9. Select the table(s) and column(s) you wish to include in your view
  10. Click "Step 3"
  11. Select the Measures from the available table columns
  12. Click "Step 5" (we skipped the "Extra Dimensions" step)
  13. Add any Variable Prompts
  14. Click "Step 6"
  15. Define any Table Joins
  16. Click "Review"
  17. Review you semantic layer view and click "Save"

With the Semantic Layer View created, you are ready to access your Harvest data through the APOS Live Data Gateway, enabling real-time data connectivity to Harvest data from SAP Analytics Cloud and other SAP solutions.

More Information & Free Evaluation

Please visit APOS Systems - APOS Solutions - Request Evaluation Software to request evaluation software or email info@apos.com for more information on working with your live Harvest data in APOS Live Data Gateway.